COVID-19 PCR Testing Superior to Antigen Testing
Tobias Todsen, MD, PhD, Kathrine K. Jakobsen MD, Mathias Peter Grønlund MD, et al.
JAMA Netw Open. 2023;6(12):e2344295.
Summary
Of 2941 participants enrolled, 2674 (90.9%) had complete test results and were included in the final analysis (1535 [57.4%] women; median age, 40 years [IQR, 28-55 years]); 1074 (40.2%) had COVID-19 symptoms, and 827 (30.9%) were positive for SARS-CoV-2 by RT-PCR.
Health care worker–collected throat specimens had higher mean sensitivity than HCW-collected nasal specimens for rapid antigen testing (69.4% [95% CI, 65.1%-73.6%] vs 60.0% [95% CI, 55.4%-64.5%]). However, a subgroup analysis of symptomatic participants found that self-collected nasal specimens were more sensitive than self-collected throat specimens for rapid antigen testing (mean sensitivity, 71.5% [95% CI, 65.3%-77.6%] vs 58.0% [95% CI, 51.2%-64.7%]; P < .001).
Combining nasal and throat specimens increased sensitivity for HCW- and self-collected specimens by 21.4 and 15.5 percentage points, respectively, compared with a single nasal specimen (both P < .001).
Key Conclusion: Significant PCR sensitivity advantage compared to antigen testing.
Summary
The “gold standard” for clinical diagnostic detection of SARS-CoV-2 remains laboratory-based (moderate- and high-complexity) NAATs. In situations where test sensitivity is of paramount importance, NAAT tests are preferred.
Antigen tests do not have the same limits of detection as most NAATs, which have a higher sensitivity. Compared to NAATs, antigen tests are more likely to return a false negative, especially when testing before symptom onset when the level of antigens in a specimen is lower.
Key Conclusion: CDC recognizes that NAATs (e.g., PCR) are superior to antigen testing.
Jacqueline Prestedge and Deborah A. Williamson
The Lancet. Volume 23, ISSUE 8, P883-884, August 2023.
Summary
The study found that, when compared with RT-PCR, the overall sensitivity of LFDs was 63·2% (95% CI 61·7–64·6; 2609 LFD-positive samples of 4131 RT-PCR positive samples) and was higher in symptomatic participants (68·7% [66·9–70·4]; 1859 of 2706) versus asymptomatic participants (52·8% [50·1–55·4]; 724 of 1372), and in unselected community-based settings (71·6% [69·8–73·4]; 1705 of 2381) versus pre-deployment testing (52·8% [49·8–55·8]; 593 of 1123). The findings by Eyre and colleagues are consistent with other clinical studies of LFD performance.
Key Conclusion: Significant PCR sensitivity advantage compared to antigen testing. LFDs (lateral flow devices) are a type of antigen test.
Michio Murakami, Hitoshi Sato, Tomoko Irie, Masashi Kamo, Wataru Naito, Tetsuo Yasutaka, and Seiya Imoto
BMJ Open. 2023; 13(1): e067591. Published online 20 Jan 2023
Summary
Of the 656 cases, 65 were positive for both the rapid antigen and PCR tests, 38 were negative for the antigen tests and positive for the PCR test, 1 was positive for the rapid antigen test and negative for the PCR test and 552 were negative for both (table 2). The sensitivity of the rapid antigen test compared with the PCR test was 0.63 (95% CI: 0.53 to 0.73) and the specificity was 0.998 (95% CI: 0.995 to 1.000).
Key Conclusion: Significant PCR sensitivity advantage compared to antigen testing.
COVID-19 Antigen Test Reliability Delayed Compared to PCR
JK Frediani, R Parsons, KB McClendon, et al.
Clinical Infectious Diseases, ciad582, published 28 Sept. 2023
Summary
This delayed peak relative to the onset of symptoms has been observed in other studies conducted later in the pandemic [22–24], but the implications of this finding for testing practice—in particular, home antigen testing practice — have not been sufficiently highlighted.
Key Conclusion: Antigen tests not reliable until 4+ days post symptom onset. PCR is more sensitive than antigen testing at any time post symptom onset.
Naso-oropharyngeal Swabs Deliver Highest Viral Load at Beginning of Infection
Atzler F, Dahms F, Paul G, Perisic S
J Med Virol 2024 Jan;96(1):e29390. doi: 10.1002/jmv.29390. PMID: 38235822
Summary
- Viral load differs significantly depending on swab collection site in the upper airways.
- For maximum clinical sensitivity, a combined naso-oropharyngeal swab should be considered. In case a single point and single sample measurement is the norm, a nasopharyngeal swab can deliver the highest viral load at the presumed beginning of the infection.
MicroWash Tie-In: MicroWash samples the nasopharynx in its entirety in one sample, reflecting the approach of the combined naso-oropharyngeal swab technique.
Nasopharyngeal Samples Preferred to Anterior or Mid-Turbinate Swabs
Zhou Y, O’Leary TJ.
PLoS One 2021 Jul 20;16(7):e0254559. doi: 10.1371/journal.pone.0254559. eCollection 2021. PMID: 34283845
Summary
- Anterior nares swabs are less sensitive (82% – 88%) than nasopharyngeal swabs (98%).
- Mid-turbinate and anterior nares swabs seem to perform similarly.
MicroWash Tie-In: MicroWash sample quality reflects that of nasopharyngeal swabs, surpassing the quality of anterior nares and mid-turbinate swab.
Nasal Aspirate/Nasal Wash Versus Flocked Nasal Swab
Chan KH, Peiris JS, Lim W, Nicholls JM, Chiu SS.
J Clin Virol 2008 May;42(1):65-9. doi: 10.1016/j.jcv.2007.12.003. Epub 1 Feb. 2008. PMID: 18242124
Summary
- Nasopharyngeal aspirate (NPA) was more sensitive than flocked nasal swab (fNS) for detecting RSV by both RT-PCR (100% vs. 92.3%).
- NPA remains the optimal specimen for diagnosis of respiratory infections by RT-PCR.
- However, collection of NPFS is easier to perform in an outpatient setting, was more acceptable to parents and less likely to generate aerosols than NPA engendering potentially less infection control hazard.
MicroWash Tie-In: MicroWash is engineered to mitigate the shortcomings of nasal aspirates, including ease of use and reduction in risk of aerosolization.
Meerhoff TJ, Houben ML, Coenjaerts FE, Kimpen JL, Hofland RW, Schellevis F, Bont LJ
Eur J Clin Microbiol Infect Dis 2010 Apr;29(4):365-71. doi: 10.1007/s10096-009-0865-7. Epub 29 Jan. 2010. PMID: 20111881
Summary
- Sensitivity of the nasal swab was lower than the nasopharyngeal aspirate, in particular, for respiratory syncytial virus (51% vs. 100%) and rhinovirus (75% vs. 97%).
- It is concluded that, for community-based studies and surveillance purposes, the nasal swab can be used, though the sensitivity is lower than the aspirate, in particular, for the detection of mild cases of respiratory syncytial virus (RSV) infection.
MicroWash Tie-In: MicroWash yields a nasopharyngeal aspirate quality sample, while providing an easy, standardized sampling technique.
Ohrmalm L, Wong M, Rotzén-Östlund M, Norbeck O, Broliden K, Tolfvenstam T
BMC Infect Dis 26 Nov. 2010;10:340. doi: 10.1186/1471-2334-10-340. PMID: 21110854
Summary
- Most studies comparing collection of samples by nasal swabs and nasopharyngeal aspirates involve immunocompetent children with URI symptoms. This study compares the two collection techniques in adults with febrile neutropenia.
- Nasopharyngeal aspirate significantly superior to nasal swabs in collecting epithelial cells.
- Overall sensitivity of nasal swabs for any virus and for rhinovirus was 65% and 78%, respectively.
- ‘We found the overall sensitivity of 65% to be too low to replace nasopharyngeal aspirate.’
MicroWash Tie-In: MicroWash provides the high-quality samples of a nasopharyngeal aspirate needed to diagnose infection early in immunocompromised patients.
Gritzfeld JF, Roberts P, Roche L, El Batrawy S, Gordon SB.
BMC Res Notes 13 April 2011; 4:122. doi: 10.1186/1756-0500-4-122. PMID: 21489228
Summary
- Nasal washing was more comfortable for volunteers than swabbing (n = 24).
- In detection by culture, the nasal wash was significantly more likely to detect pathogens than the nasopharyngeal swab (p < 0.00001).
MicroWash Tie-In: MicroWash provides the high-quality samples of a nasopharyngeal aspirate needed to identify carrier states for consequential pathogens.
2002 Study Illustrates Significant NP Aspiration (NPA) Sample Sensitivity Advantage Compared to Nasal Swab (NS) Sample For RSV
Stensballe LG, Trautner S, Kofoed P-E, Nante E, Hedegaard K, Jensen IP, Aaby P
Trop Med Int Health. 2002 Apr;7(4):317-21. doi: 10.1046/j.1365-3156.2002.00867.x.
Summary
- Using NS samples was associated with a 27-31% reduction in sensitivity compared with NPA specimens.
MicroWash Tie-In: There is a strong body of literature supporting a significant specimen quality and sensitivity advantage of nasal aspiration/nasal lavage (like the MicroWash) compared to nasal swab specimens.
Clinical Applications in Long-term Care Facilities + Early Detection to Reduce Healthcare Resource Utilization
Temte JL, Checovich MM, Barlow S, Shult PA, Reisdorf E, Haupt TE, Hamrick I, Mundt MP.
J Am Med Dir Assoc 24 Dec. 2023 (12):1904-1909. doi: 10.1016/j.jamda.2023.05.035. Epub 2023 Jul 5. PMID: 37421970
Summary
- The use of low-threshold criteria to trigger nursing staff-initiated testing for influenza with RIDT resulted in increased prophylactic use of oseltamivir.
- This study demonstrated significant reductions in all-cause ED visits (22% less), hospitalizations (21% less), and hospital length of stay (36% less).
MicroWash Tie-In: MicroWash allows for easy, painless sampling on a large scale, for monitoring purposes and to guide rapid therapeutic intervention in populations at high risk from viral infection.
Saline Nasal Wash Sample At Least Equivalent, If Not Superior, to VTM Sample for PCR Testing
There is a significant body of literature showing saline nasal wash samples, like the MicroWash, are equivalent and in some cases superior in quality to standard viral transport media (used for nasal swab samples) for PCR testing, even with a delay in testing of 7 or more days.
Caroline Ngetsa, Victor Osoti, Dorcas Okanda, Faith Marura, Krupali Shah, Henry Karanja, Daisy Mugo, John Gitonga, Martin Mutunga, Clement Lewa, Benedict Orindi, Philip Bejon, Lynette Isabella Ochola-Oyier
PLoS One. 2023 Feb 13;18(2):e0280685. doi: 10.1371/journal.pone.0280685. eCollection 2023.
Summary
Overall, this study demonstrated that normal saline, PBS and the locally manufactured VTM canbe used for COVID-19 sample collection and testing, thus expanding the range of SARS-CoV-2 viral collection media.
Garrett A. Perchetti, Meei-Li Huang, Vikas Peddu, Keith R. Jerome, Alexander L. Greninger
Journal of Clinical Microbiology; Vol 58 No 8; 13 July 2020
Summary
It has been demonstrated that nasopharyngeal specimens containing SARS-CoV-2 can be stored in phosphate-buffered saline (PBS) as a substitute for viral transport medium (VTM) for up to 7 days.
Kyle G. Rodino, Mark J. Espy, Seanne P. Buckwalter, Robert C. Walchak, Jeffery J. Germer, Emily Fernholz, Aimee Boerger, Audrey N. Schuetz, Joseph D. Yao, Matthew J. Binnicker
Journal of Clinical Microbiology June 2020 Volume 58 Issue 6 e00590-20
Summary
These data support the use of MEM, PBS, or 0.9% saline as alternatives to VTM for SARS-CoV-2 testing.
Jared Radbel, Sugeet Jagpal, Jason Roy, Andrew Brooks, Jay Tischfield Michael Sheldon, Christian Bixby, Dana Witt, Maria L. Gennaro, Daniel B. Horton, Emily S. Barrett, Jeffrey L. Carson, Reynold A. Panettieri Jr., Martin J. Blaser
The Journal of Molecular Diagnostics Volume 22, Issue 7, July 2020, Pages 871-875
Summary
The current study establishes PBS as a clinically useful transport medium with the potential to increase viral detection capacity, thus improving clinical care and surveillance efforts.
P Sinha, DK Jain, S Gupta, Monika Gupta, Megha Gupta, A Agarwal, R Sharma, N Vyas
Journal of Clinical and Diagnostic Research. 2021 Apr, Vol-15(4): DC19-DC22
Summary
Looking into the cost and logistics issues especially during pandemics, saline is a good and cheaper alternative to VTM and with its use, testing capacity can be expanded.
Optimizing Automated PCR Testing Workflow
Greene DN, Matthys T, Lockwood CM.
J Appl Lab Med 29 April 2021;6(3):606-613. doi: 10.1093/jalm/jfaa197. PMID: 33119112.
Summary
SARS-CoV-2 was detected in all proof of principle samples with CT values indicative of dilution. The rare exception was for a few samples where the dilution pushed the viral load below the LOD. Paired samples were 100% concordant for SARS-CoV-2 and RNaseP detection.
Discarding the swab after inoculating the transport buffer is an appropriate preanalytical modification. Adopting this approach can save up to 1 minute per sample. For labs processing more than 500 samples per day, this equates to 1 full-time equivalent shift per day.
MicroWash Tie-In: MicroWash is a swab-free system with all the advantages outlined in this article.
Swab Removal from Specimen Tube and Sample Quality
Zorzoli A, Bennett-Slater S, MacLean A, McAllister G, Gunson R, Templeton K.
Access Microbiol 12 Dec. 2023;5(12):000718.v3. doi: 10.1099/acmi.0.000718.v3. eCollection 2023. PMID: 38188247
Summary
- Most automated PCR testing requires the removal of the swab from the specimen tube prior to analysis as the retained swab may cause processing errors [1-2].
- The process of removing the swab from the specimen tube is time intensive and places lab technicians at risk for infection.
- Removal of the swab from the specimen tube may impact results for weakly positive specimens [2], resulting in false negative results.
- Swab-free specimens can save labs up to 1 minute/sample. For labs processing more than 500 samples/day, this equates to one full-time equivalent shift/day [1].
MicroWash Tie-In: Microwash eliminates the swab in the specimen tube problem, increasing lab efficiency, reducing risk to lab technicians, all while providing a high-quality specimen.
Clinical Applications in Chronic Disease States + Sampling for Microbiome Monitoring
Chung J, Boutin S, Frey DL, Joachim C, Mall MA, Sommerburg O. J Cyst
Fibros 9 Jan. 2024:S1569-1993(23)01735-6. doi: 10.1016/j.jcf.2023.12.011. Online ahead of print. PMID: 38199892
Summary
- Nasal wash results better reflect the microbiome of the nose and paranasal sinuses than nasal swabs.
- The microbiome of the upper airways may influence inflammation in patients with cystic fibrosis to assist in predicting disease course and guide treatment options.
Chen M, He S, Miles P, Li C, Ge Y, Yu X, Wang L, Huang W, Kong X, Ma S, Li Y, Jiang Q, Zhang W, Cao C
Front Cell Infect Microbiol 3 March 2022; 12:841995. doi: 10.3389/fcimb.2022.841995. eCollection 2022. PMID: 35310838
Summary
- Microbiome is also important in more common diseases, such as asthma.
- ‘This study showed the upper airway microbiome is associated with airway inflammation disorders and the level of asthma control.’
MicroWash Tie-In: MicroWash provides an easy, painless way to provide the data needed to optimize care for patients with chronic respiratory disease and may enable the home monitoring program of the future.
Growing Importance of Co-Infection and Super-Infection in URI Cases
During the COVID-19 pandemic, a body of evidence documented pulmonary co-infections and super-infections in hospitalized patients, primarily in the ICU. Multiple viral and bacterial pathogens were identified in these cases. In many situations, these secondary infections resulted in more prolonged hospitalizations, ICU stays and even death.
This situation highlights the need for multi-pathogen testing, with the MicroWash being the ideal sample collection system, in the management of URI cases in the post-pandemic environment.
Gao CA, Markov NS, Stoeger T, Pawlowski A, Kang M, Nannapaneni P, Grant RA, Pickens C, Walter JM, Kruser JM, Rasmussen L, Schneider D, Starren J, Donnelly HK, Donayre A, Luo Y, Budinger GRS, Wunderink RG, Misharin AV, Singer BD NU SCRIPT Study Investigators
J Clin Invest. 15 June 2023;133(12):e170682. doi: 10.1172/JCI170682.PMID: 37104035
Nicolò Brandi, Federica Ciccarese, Caterina Balacchi, Maria Rita Rimondi, Cecilia Modolon, Camilla Sportoletti, Chiara Capozzi, Matteo Renzulli, Alexandro Paccapelo, Andrea Castelli, Rita Golfieri.
Diagnostics (Basel). 3 July 2022; 12(7): 1617. doi: 10.3390/diagnostics12071617
Hui Fan, Li Zhou, Jingjun Lv, Shimin Yang, Guozhong Chen, Xinjin Liu, Chunyan Han, Xue Tan, Shengnan Qian, Zegang Wu, Shan Yu, Ming Guo, Chengliang Zhu, Yu Chen & Ke Lan
Cell Research volume 33, pages 562–564 (2023)
Nasal Swab Testing Hesitancy
Kernberg A, Kelly J, Nazeer S, Russell S, Tuuli M, Stout MJ, Raghuraman N, Carter EB
Obstetrics & Gynecology 136(6):p 1103-1108 December 2020. | DOI: 10.1097/AOG.0000000000004127
Summary
- All consecutive patients presenting for delivery without coronavirus disease 2019 (COVID-19) symptoms were offered testing over four 1-week phases.
- Of 270 patients 223 (83%) accepted testing and 47 (17%) declined.
- The most commonly cited reason for declining testing was concern regarding testing discomfort.